ASTM A – Designation: A /A M – 98 (Reapproved ) Standard Test Method for Conducti. Purchase your copy of ASTM A/AM – 17 as a PDF download or hard copy directly from the official BSI Shop. All BSI British Standards. This standard is issued under the fixed designation A/AM; the number This test method is under the jurisdiction of ASTM Committee A01 on Steel, 2.

Author: Shabar Tehn
Country: Malta
Language: English (Spanish)
Genre: Video
Published (Last): 2 May 2018
Pages: 175
PDF File Size: 10.90 Mb
ePub File Size: 14.28 Mb
ISBN: 995-1-42303-307-5
Downloads: 45582
Price: Free* [*Free Regsitration Required]
Uploader: Kirg

The acceptance of any such additional requirements shall be dependent on negotiations with the supplier and must be included in the order as agreed upon by the purchaser and supplier. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. The values stated in each system are not exact equivalents; therefore, each system is to be used independently of the other, without combining values in any way.

Individual reprints single or multiple copies sstm this standard may be obtained by contacting ASTM at the above address or at phonefaxor service astm. This standard is subject to revision at any time by the responsible technical committee and must be reviewed every? Link to Active This link will always route to the current Active version of the standard.

All other conditions described in 6. Within the text, the SI units are shown in brackets. Survey documentation requirements, and the procedure used to subsequently establish the furnace working zone, are de? Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM International Headquarters.

The working zone may be comprised of one atsm more heating zones in the furnace. This method is used to determine the capability of the furnace to meet the permissible temperature variation speci? A9991 you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards, at the address shown below. Regardless of heat treat furnace type, or processing cycle, it may be necessary for users to know the temperature uniformity in the furnace and whether the material is processed in a zone within the furnace that is capable of meeting the applicable permissible temperature variation requirements.

  COMPLOT CONTRA LA IGLESIA MAURICE PINAY PDF

The acceptance of any such additional requirements shall be dependent on negotiations with the supplier and must be included in the order as agreed upon by the purchaser and supplier. This method is used to determine the capability of the furnace to meet the permissible temperature variation specified in the applicable product specification, or as agreed to by the purchaser and supplier of heat treat services. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility.

Use of representative material to simulate product during survey is permitted.

Place them at the outer extremities, the center of the proposed working zone, and in areas of suspected variability in the proposed working zone. Attach survey test sensors to, or set them in the load.

It provides validation of temperature uniformity by a series of tests rather than a single test. Documentation of Survey Results 8.

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. A superscript aatm e indicates an editorial change since the last revision or reapproval.

ASTM International – Standard References for ASTM A / AM – 17

astk The rate of conveyance shall be representative of normal operating conditions. Regardless of heat treat furnace type, or processing cycle, it may be necessary for users to know the temperature uniformity in the furnace and whether the material is processed in a zone within the furnace that is capable of meeting the applicable permissible temperature variation requirements. Survey documentation requirements, and the procedure used to subsequently establish the furnace working zone, are defined in this test method.

  LUTOSAWSKI CONCERTO FOR ORCHESTRA PDF

Combining values from the two systems may result in non-conformance with the standard. Originally approved in The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. For proposed working zones greater than, or equal to, 12 in.

Historical Version s – view previous versions of standard. Calibration to such national standards shall be done at least once every two years. Heat Treatment in the Working Zone A number in parentheses indicates the year of last reapproval.

Examples of these surveying techniques are listed below.

ASTM A991/A991M – 17

Interpretation of Results and Establishment of the Working Zone 9. In each test, determine the temperature a919 pattern at one or more of the test locations. Starting time and chart speed shall be marked on the original temperature charts, 8. Current edition approved Oct. Results of the application of this test method shall be expressed as a variation from a temperature set point.

Furnace Survey Equipment 5. Details of this procedure shall be as agreed to between purchaser and supplier. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend.